The Synrad p Series pulsed CO2 lasers cut faster, drill flawlessly and micro-process with precision. Harnessing pulse technology to deliver peak pulse power levels many times greater than standard continuous-wave laser power levels, the p Series expands cutting, drilling and perforating applications to a wider range of materials, including films, high performance textiles, certain metals, and high-tech composites. Internal beam conditioning before the aperture, focuses the beam down to a narrow spot for increased laser processing detail with near-perfect beam quality. Built for industrial environments, all models feature built-in gas purge ports for convenient in-field servicing and protective optical windows.
User controlled pulse/continuous wave operation modes enable application flexibility. Peak pulse power delivers energy more efficiently and minimizes heat affected zone (HAZ) to better process heat sensitive materials such as thin films, glass, and ceramics.
Integrated beam conditioning guarantees a high quality, circular output beam for precise cutting, drilling and intricate feature details. Excellent power and divergence stability delivers consistent, high quality processing results
Real-time performance monitoring (p250 & p400) reduces unplanned downtime with onboard advanced diagnostics that are Industry 4.0 ready
> 90 Watts (10.2 μm) > 100 Watts (10.6 μm)
> 150 Watts
> 250 Watts
> 400 Watts
375 Watts (10.2 μm) 400 Watts (10.6 μm)
600 Watts (9.3, 10.6 μm) 550 Watts (10.2 μm)
750 Watts (10.2 μm) 800 Watts (10.6 μm)
1 kW
10.2 μm, 10.6 μm
9.3 μm, 10.2 μm, 10.6 μm
10.6 μm
< 1.2
± 7%
± 5% (9.3 μm) ± 6% (10.6, 10.2 μm)
± 5%
6.5 mm ± 1.0 mm 9.0 mm ± 1.0 mm
8.5 mm ± 1.0 mm
8.0 mm ± 1.0 mm 9.0 mm ± 1.0 mm
6.5 mm ± 1.0 mm 9 mm ± 1.0 mm
0 – 100 kHz
0 – 130 kHz
< 37.5%
< 45%
≤ 50%
Water
590 x 132 x 155 (23.2 x 5.2 x 6.1)
798 x 132 x 155 (31.4 x 5.2 x 6.1)
1252 x 315 x 198 (49.3 x 12.4 x 7.8)
1262 x 208 x 300 (49.7 x 8.2 x 11.8)
13.6 kg (30 lbs.)
18.1 kg (40 lbs.)
48.5 kg (107 lbs.)
59 kg (130 lbs.)
1 – Power level guaranteed for 2 years from date of shipment, regardless of operating hours, within recommended coolant flow rate and temperature range.
2 – Peak pulse power measured at 1 kHz, 10% duty cycle
3 – With 3X beam expander
4 – Measured from cold start as ±(Pmax-Pmin)/(Pmax+Pmin)
5 – Measured 1/e2 diameter at laser output
Note – See Operator’s Manual for full specifications and associated operating conditions.