48 Series Laser Closed Loop System

The system includes a beam sampler and closed-loop control system to stabilize the output power of the water-cooled 48-1 CO2 lasers. The Closed Loop System works with the UC-2000 laser controller.

48 Series Laser Closed Loop System
Description
Performance of the system is typically ±2%. The beam sampler and closed loop control system are factory installed, and  works with the UC-2000 laser controller. System power is provided through a wall plug transformer delivering 24VDC. A beam-splitter internal to the sampler diverts 8% of the output beam to a diffuser and thermo-pile detector. The thermo-pile detector signal is amplified within the sampling enclosure to a 1 to 12V signal level. A remotely located controller generates a variable duty cycle 5 kHz signal to maintain a constant average power of the laser. On a custom basis, the control frequency can be raised to 20 kHz for less optical ripple.
Highlights External Link Pop Up
Adjustable power set point
NOVT_Closed_Lop_Kit_Highlights_Pop_1_Image

Full Dynamic Power Regulation

The power “set point” can be adjusted to provide a laser output between approximately 20% and 80% of full power. This 20% window on either side of the range allows the UC-2000 to maintain full dynamic power regulation. Within the dynamic response time of the system, the UC-2000 can be gated from an external low-frequency signal source. Servo settling time (to 90% of final value) is approximately 2 msec.

Specifications
Model 10 mm14 mm